Programmeerbare Laadregelaar LiFe(Y)PO4
Geschikt voor LiFe(Y)PO4
Systeemspanning (automatisch): 12/24 Volt

Max. laadstroom: 20 A
Max. laadspanning: 50 V
Max. laadvermogen (12V): 340 W
Max. laadvermogen (24V): 680 W
Max. stroom verbruikersuitgang: 20 A

Nachtlichtfunctie
Model: opbouw
Gewicht: 0,3 kg
Over- en onderspanningsbeveiliging
Temperatuurcompensatie
Display: Verlicht grafisch LCD

 

 

Deep-Discharge Protection

The adaptive total discharge protection monitors and protects the battery from harmful discharge. and alternatively the nightlight function can be used. If the battery voltage is reduced too much, the devices connected at terminals L + / L- are switched off automatically. If the battery voltage is increasing again, consumers are switched on automatically. Alternatively the night light function can be used. When using the nightlight function, a consumer will be switched on during the time the modules do not supply charge current (i.e. when it is dark). Ideal for the operation of an orientation light or small lights for the prevention of break-ins.
 

 
LCD-Display

The backlit graphical LCD display shows in clear characteristics actual informations for:

  • Voltage of the battery 1 [V]
  • Load current [A]
  • generated module current [A]
  • Power consumption [A]
  • Battery state of charge ( as a bar diagram)

  • For the adjustement of basic settings, for example selection of the battery type, various screens are available. After pressing a button, the backlight remains active 30 sec.

     

     
    Loading Phases of LiFe(Y)PO4 Battery

     

    1.: Soft Start:
    A deeply discharged battery should not be charged directly with a high charging current below a voltage of ~ 10.0V. Therefore, the controller limits this voltage range below the charging current to about 2A.
     
    2.: Quick Charge:
    In the rapid charging phase, with the entire available stationary solar charging current (recommended max. ~ 0.3C) until reaching the rapid charging voltage (~ 14,6V). In view of the discontinuous solar charging currents, the fast-charging voltage can not be achieved under certain circumstances for days or weeks. The charge for an unlimited time is not recommended, therefore, this loading phase is also guaranteed by the additional timing after a preset "maximum fast charge time" activates the next charging stage.

    Upon reaching the fast charge voltage the battery is charged already to about 80%..
     
    3.: Full Charge: 
    In the subsequent full-charge phase, the full charge voltage (= fast charge voltage) is kept constant by an adjustable lower charging current (~ 0,01C) is exceeded with sufficient solar charging power. This loading phase brings the remaining 20% of a full charge into the battery. The time to reach the 100% full charge is approximately twice as large as the charging voltage to reach the required speed. To prevent continously charging of the battery an adjustable full-charge timeout could be set.
     
    4.: Disconnect: 
    A permanent trickle charge as of the known lead-battery is not permitted. Therefore, in the final charging phase the charging current is switched off completely.

    The restart of the entire charging cycle takes place once the voltage was below 13.6V @12V or at least every two months charging phase.
     

     

     
    Menu Parameter


    The following parameters can be set (default values):

    Deepdischarge ProtectionMenu 3: Load Switch OFF
     Range: 11,4V...11,7V...12.5V @12V-System
    Voltage where the load (output) is switched off.corresponds to 90% to 10% of capacity
      
    Fast Charge VoltageMenu 5: FastCharge
     Range: 14,0V ... 14,6V ... 15,2V @12V-System
     A higher fast charge voltage causes a faster charge in accordance with existing solar charging current.

    However, this is accompanied by increased heating of the battery. Please be sure to observe the instructions of the battery manufacturer.
      
    Timeout of FastChargeMenu 6: Timeout FastCharge
     4h ... 8h ... 20h
     If insufficient charging current is present or during concomitant discharge may interfere with the quick-charge voltage for an indefinite time are not achieved.

    However, lithium batteries should not be charged indefinitely, so the controller will switch after this period of time to the next loading phase.
      
    Cut-off Current of the ChargeMenu 7: Charge Switch OFF
     0,2A ... 1,0A ... 2,0A
     After reaching the fast-charging voltage lithium batteries need to 100% full charge even more charge time. In this phase the charge current continuously decreases.

    Therefore, the controller keeps the charging voltage constant and switches off the charge completely when below the set current.
      
    Timeout of Full-ChargeMenu 8: Timeout FullCharge
     8h ... 16h ... 40h
     If the turn-off current in the full loading phase is not reached within this time period, the controller switches off the current to prevent uncontrolled trickle charge from the charging current.
      
    Restart of ChargingMenu 9: Restart Charge
     13,0V ...13,6VA... 14,2V
     If the battery voltage drops below that value, for example a load is swichted ON, the regulator starts a new charging cycle..
      
    Maximum Charging TemperaturMenu 10: ChargeTemp High
     30°C ... 45°C ... 75°C
     Lithium batteries can only be charged up to a, by the manufacturer given, maximum loading temperature. When this level is reached the controller interrupts the charging current.
      
    Minumum Charging TemperaturMenu 11: ChargeTemp Low
     0°C ... -25°C
     Lithium batteries may only be charged above a minimum temperature, permitted by the manufacturer. Therefore, the controller interrupts the charging current when the temperature falls below the set value.
      

     


 

Dimensions

Deep-Discharge Protection

The adaptive total discharge protection monitors and protects the battery from harmful discharge. and alternatively the nightlight function can be used. If the battery voltage is reduced too much, the devices connected at terminals L + / L- are switched off automatically. If the battery voltage is increasing again, consumers are switched on automatically. Alternatively the night light function can be used. When using the nightlight function, a consumer will be switched on during the time the modules do not supply charge current (i.e. when it is dark). Ideal for the operation of an orientation light or small lights for the prevention of break-ins.
 

 
LCD-Display

The backlit graphical LCD display shows in clear characteristics actual informations for:

  • Voltage of the battery 1 [V]
  • Load current [A]
  • generated module current [A]
  • Power consumption [A]
  • Battery state of charge ( as a bar diagram)

  • For the adjustement of basic settings, for example selection of the battery type, various screens are available. After pressing a button, the backlight remains active 30 sec.

     

     
    Loading Phases of LiFe(Y)PO4 Battery

     

    1.: Soft Start:
    A deeply discharged battery should not be charged directly with a high charging current below a voltage of ~ 10.0V. Therefore, the controller limits this voltage range below the charging current to about 2A.
     
    2.: Quick Charge:
    In the rapid charging phase, with the entire available stationary solar charging current (recommended max. ~ 0.3C) until reaching the rapid charging voltage (~ 14,6V). In view of the discontinuous solar charging currents, the fast-charging voltage can not be achieved under certain circumstances for days or weeks. The charge for an unlimited time is not recommended, therefore, this loading phase is also guaranteed by the additional timing after a preset "maximum fast charge time" activates the next charging stage.

    Upon reaching the fast charge voltage the battery is charged already to about 80%..
     
    3.: Full Charge: 
    In the subsequent full-charge phase, the full charge voltage (= fast charge voltage) is kept constant by an adjustable lower charging current (~ 0,01C) is exceeded with sufficient solar charging power. This loading phase brings the remaining 20% of a full charge into the battery. The time to reach the 100% full charge is approximately twice as large as the charging voltage to reach the required speed. To prevent continously charging of the battery an adjustable full-charge timeout could be set.
     
    4.: Disconnect: 
    A permanent trickle charge as of the known lead-battery is not permitted. Therefore, in the final charging phase the charging current is switched off completely.

    The restart of the entire charging cycle takes place once the voltage was below 13.6V @12V or at least every two months charging phase.
     

     

     
    Menu Parameter


    The following parameters can be set (default values):

    Deepdischarge ProtectionMenu 3: Load Switch OFF
     Range: 11,4V...11,7V...12.5V @12V-System
    Voltage where the load (output) is switched off.corresponds to 90% to 10% of capacity
      
    Fast Charge VoltageMenu 5: FastCharge
     Range: 14,0V ... 14,6V ... 15,2V @12V-System
     A higher fast charge voltage causes a faster charge in accordance with existing solar charging current.

    However, this is accompanied by increased heating of the battery. Please be sure to observe the instructions of the battery manufacturer.
      
    Timeout of FastChargeMenu 6: Timeout FastCharge
     4h ... 8h ... 20h
     If insufficient charging current is present or during concomitant discharge may interfere with the quick-charge voltage for an indefinite time are not achieved.

    However, lithium batteries should not be charged indefinitely, so the controller will switch after this period of time to the next loading phase.
      
    Cut-off Current of the ChargeMenu 7: Charge Switch OFF
     0,2A ... 1,0A ... 2,0A
     After reaching the fast-charging voltage lithium batteries need to 100% full charge even more charge time. In this phase the charge current continuously decreases.

    Therefore, the controller keeps the charging voltage constant and switches off the charge completely when below the set current.
      
    Timeout of Full-ChargeMenu 8: Timeout FullCharge
     8h ... 16h ... 40h
     If the turn-off current in the full loading phase is not reached within this time period, the controller switches off the current to prevent uncontrolled trickle charge from the charging current.
      
    Restart of ChargingMenu 9: Restart Charge
     13,0V ...13,6VA... 14,2V
     If the battery voltage drops below that value, for example a load is swichted ON, the regulator starts a new charging cycle..
      
    Maximum Charging TemperaturMenu 10: ChargeTemp High
     30°C ... 45°C ... 75°C
     Lithium batteries can only be charged up to a, by the manufacturer given, maximum loading temperature. When this level is reached the controller interrupts the charging current.
      
    Minumum Charging TemperaturMenu 11: ChargeTemp Low
     0°C ... -25°C
     Lithium batteries may only be charged above a minimum temperature, permitted by the manufacturer. Therefore, the controller interrupts the charging current when the temperature falls below the set value.
      

     


 

Dimensions

Er zijn geen beoordelingen voor dit product.